Items |
Specification |
Measurement conditions, etc.
|
Rated voltage |
AC100-240V(AC85*-264V) |
Worldwide range
*Derating for
Low Input
Voltage(link) |
Input frequency |
50/60Hz |
47-63Hz |
Efficiency |
81% typical (AC100V),84% typical
(AC200V) |
With rated output |
Power factor |
96% typical(AC100V),90% typical(AC200V) |
Inrush current |
31A peak(AC100V),75A peak(AC240V) |
With rated input/output at cold start(25℃) |
Input current |
8.8A typ(AC100V),3.6A typ(AC240V) |
With rated input and max output |
10.2A typ(AC100V),4.2A
typ(AC240V) |
With rated input and peak output |
Model |
GPSA-750-12-TP |
GPSA-750-24-TP |
GPSA-750-30-TP |
GPSA-750-48-TP |
Common for all
models |
|
Rated voltage |
+12V |
+24V |
+30V |
+48V |
+12VSB |
|
Rated current/power |
56A |
30A |
25A |
16A |
0.1A |
|
768W |
768W |
768W |
768W |
1.2W |
Peak current/power |
70A |
35A |
28A |
17.5A |
0.1A |
*Time shall be 5s max. For repetitive loads,
duty ration shall be 10% max |
840W |
840W |
840W |
840W |
1.2W |
Minimum current |
0A |
0A |
0A |
0A |
0A |
|
Setup voltage at shipment |
12V±2% |
24V±2% |
Coming Soon |
12V±10% |
The values shall be measured at output
terminal block or connector. |
Adjustable voltage range |
12V±10% |
24V -5%,+20% |
− |
Static input regulation |
48mVmax |
96mV max |
120mV max |
Static load regulation |
240mV max |
240mV max |
600mV max |
Time lapse drift- |
60mV max |
120mV max |
120mV max |
Temperature regulation |
0.02%/℃ max |
0.02%/℃ max |
0.02%/℃ max |
Max ripple voltage
(mVp-p) |
-10〜0℃ |
160 max |
160 max |
120 max |
Connect two wires of 100cm max in length to the output
terminal block and put a 47µF electrolytic capacitor
and a 0.1µF ceramic capacitor. Put a 100MHz oscilloscope
to measure. |
0〜60℃ |
120 max |
120 max |
120 max |
Max spike voltage
(mVp-p) |
-10〜0℃ |
180 max |
180 max |
180 max |
0〜60℃ |
150 max |
150 max |
150 max |
Over Current
Protection |
OCP point (A) |
101% minimum of peak current |
101% min peak current |
|
Method |
Hold-down current limiting→output
shutdown |
Hold-down current limiting |
Recovery (OC) |
AC operation |
Reclosing AC input |
Automatic recovery |
|
Over Voltage
Protection |
OVP point (V) |
13.8 to 16.2 |
29.2 to 35.0 |
− |
|
Method |
Output shutdown |
− |
Recovery (0V) |
At AC operation |
Reclosing AC input
|
− |
Operating temperature/humidity |
-10〜60℃*/10〜90% |
*Temperature Derating(link)
There shall be no condensation. |
Storage temperature/humidity |
-25〜75℃/10〜95% |
There shall be no condensation. |
Vibration |
Acceleration of 2G, vibration frequency of 10-55Hz,
10 sweep cycles in the X・Y・Z directions. |
JIS-C-60068-2-6 at no operation |
Mechanical shock |
Lift one bottom edge up to 50mm and let it fall. Repeat
three times for each of four edges. No malfunction. |
JIS-C-60068-2-31, at no operation |
Dielectric strength |
AC4000V for one minute between AC input
and DC output
AC2000V for one minute between AC input and FG
|
Perception current is 10mA. Completion
inspection:AC3000V/min between
AC input-DC output |
Insulation resistance |
50MΩ minimum between AC input and DC
output
50MΩ minimum between AC input and FG
50MΩ minimum between DC output and FG
|
DC500V |
Leakage current |
0.21mA max(AC100V)/0.5mA max(AC240V) |
YEW. TYPE3226 (1kΩ) or equivalent. |
Line noise immunity |
±2000V (pulse width: 100ns and 1000ns, repetitive cycle:
30-100Hz, normal
and common modes with positive and negative polarities for 10 minutes
each) |
Measured with INS-410. There shall be
no fluctuation of DC output or malfunction. |
Electrostatic discharge |
EN61000-4-2 compliant |
|
Radiated,radio-frequency
EM field |
EN61000-4-3 compliant |
|
Fast transient burst |
EN61000-4-4 compliant |
|
Lightning surge |
EN61000-4-5 compliant |
|
Conducted disturbances induced by radio-frequency |
EN61000-4-6 compliant |
|
Power source frequency magnetic
field |
EN61000-4-8 compliant |
|
Voltage dip/regulation |
EN61000-4-11 compliant |
|
Conducted emission |
VCCI-B, FCC-B, EN55022-B, and CISPR22-B compliant |
Measured with power supply single body. |
Harmonic current regulation |
IEC61000-3-2(Ver.2.1) Class D, EN61000-3-2(A14) Class
D compliant |
With rated input and output |
Safety standard |
UL60950-1,CSA60950-1(c-UL),EN60950-1,EN60601-1,EN50178
scheduled to acquire. |
In May 2009 (GPSA-750-12-TP and GPSA-750-24-TP only) |
Cooling system |
Forced-air cooling |
|
Output GND terminal |
Capacitor grounded |
|
Output hold-up time |
PWR_OK holds up 20ms min after AC failure. |
With rated output |
Reliability Grade |
FA (industrial equipment grade, double-sided PWBs with
through holes) |
It is to follow our standard. |
MTBF |
70,000 H min |
Based on EIAJ RCR-9102 |
Weight |
2.3 kg typ |
|
Warranty |
Three years after delivery. If any faults belong to
us, the defective unit shall be repaired or replaced at out cost.
|
Except for errors caused by operation not listed. |