+12V Dual Outputs! Ultra high efficiency SFX Power Supply |
 |
- SFX power supply APPENDIX C mounting side compliant - +12V dual outputs for stable CPU operation - 0A (zero amp) of min. load for each output, and still stable operation - Flexible selection of output harnesses due to connector type
|
|
Continuous
250W |
|
Peak
350W |
|
 |
*Output harnesses are optional. |
*Please use Metric Screw Threads, ("M3" screws) for PSU mounting.(Inch Screw Threads cannot be used.) |
Function :For description of function, click each icon
Output specification
Output connector : For description of function, click each icon
Standard, specifications: For standard and specifications, click each item.
Compatible case size |
SFX |
Outline drawing |
125Wx63.5Hx125D |
Weight |
1.20 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
73% typical at AC 100V/77% typical at AC 240V |
Power factor |
96% typical at AC 100V/90% typical at AC 240V |
Input changeover system |
Worldwide |
Safety |
UL60950, CSA C22.2 No.950(c-UL), EN60950-1(NEMKO), CE Marking |
High frequency current regulation |
IEC61000-3-2 Class D compliant |
EMI standard (Input feedback noise) |
VCCI FCC and CISPR 22 Class A compliant |
CE marking |
Low voltage directive |
EMS immunity |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11 |
MTBF |
70,000H |
Operating temperature |
0 to 40 deg C (100% load), to 60 deg C (60% load). |
Leakage current |
0.5mA max. at AC 100V)/1.2mA max. at AC 240V |
Cooling systems |
Forced air cooling |
Insulation |
 |
Output ground connection |
 |
Warranty |
Three years after delivery, however, if defects belong to us, the defective unit shall be repaired or replaced at our cost. |