Compatible case size |
PS2 |
Outline drawing |
150Wx85Hx200D |
Weight |
2.6 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
90% typ(AC100V)/91% typ(AC240V) |
Power factor |
96% typical at AC 100V and 90% typical at AC 240V |
Input changeover system |
Worldwide |
Safety |
UL62368,CSA62368(c-UL),CE Marking(LVD,EMC) |
High frequency current regulation |
Compliant with IEC61000-3-2 class A |
EMI standard (Input feedback noise) |
Compliant with VCCI Class B FCC Rules Class B and EN55022 Class B |
CE marking |
Low voltage and EMI directive and RoHS2.0 |
EMS immunity |
Electrostatic discharge to meet EN61000-4-2 Radioactive radio-frequency electromagnetic fields to meet EN61000-4-3 Fast transient burst to meet EN61000-4-4 Lightning surge immunity to meet EN61000-4-5 Conductive radio-frequency electromagnetic field immunity to meet EN61000-4-6 Power frequency magnetic field immunity to meet EN61000-4-8 Voltage dips and fluctuation to meet EN61000-4-11 |
MTBF |
|
Operating temperature |
0 to 60 deg.C (40-60deg.C Derating) |
Leakage current |
0.5mA max. at AC 100V and 1.0mA max. at AC 200V and 1.2mA max. at AC 240V
|
Cooling systems |
Forced air cooling |
Insulation |
|
Output ground connection |
Connected to chassis |
Warranty |
Three years after delivery. If defects belong to us, the defective unit shall be repaired or replaced at our cost. |