| Medical standard approved small size PCB type +15V output single output power supply |
 |
Supports smaller size with larger capacity and high peak It is not necessary to provide a noise filter on the outside. Low noise and low leakage current is also realized. Backup for momentary power failure is available |
|
Continuous
75W |
|
Peak
150W |
|
 |
|
|
Output specification
Standard, specifications: For standard and specifications, click each item.
| Compatible case size |
Other |
| Outline drawing |
55Wx28Hx133D |
| Weight |
0.16 kg typ |
|
AC |
85-264V |
|
AC |
85% typ(100VAC)/87% typ(200VAC) |
|
 |
|
Worldwide |
|
IEC/EN60601-1 Ed3.1(CB/CE Marking), ANSI AAMI ES60601-1 Ed3.1(UL), CSA60601-1 Ed3.1(cUL), IEC/EN62368-1 2nd(CB/CE Marking), UL/CSA62368-1 2nd(UL/cUL),GB4943.1(CCC), PSE (ordinance clause 2) compliant |
|
 |
|
VCCI/FCC/CISPR 32/EN55032 class B compliant |
|
Low Voltage Directive, EMC Directive,RoHS2.0 |
|
Electrostatic discharge: IEC61000-4-2 compliant Radiate, radio frequency electromagnetic fields: IEC61000-4-3 compliant Fast transient burst: IEC61000-4-4 compliant Lightning surge: IEC61000-4-5 compliant Conductive radio frequency electromagnetic fields: IEC61000-4-6 compliant Power source frequency magnetic immunity: IEC61000-4-8 compliant Voltage dips and fluctuation: IEC61000-4-11 compliant |
|
400,000h |
|
-10 to 70 deg.C |
|
0.2mA max. (100VAC), 0.5mA max. (264VAC) |
|
Air-cooling without blower |
|
4kV AC/1minute between input and output (2MOPP),2kV AC/1minnute between input and FG,0.5kV AC/1minute between each output and FG |
|
Capacitor grounding |
|
Three years after delivery: If any defects belong to us, the defective unit shall be repaired or replaced at our cost. |