Compatible case size |
Other |
Outline drawing |
55Wx32Hx195D |
Weight |
0.30 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
82% typical at AC 100V/82% typical at AC240V |
Power factor |
|
Input changeover system |
Worldwide |
Safety |
Certified UL60950-1,CSA60950-1(c-UL),CE marking(IEC62368-1), The Electrical Appliance and Material Safety Law (section 2) compliant |
High frequency current regulation |
|
EMI standard (Input feedback noise) |
VCCI-B FCC-B CISPR22-B and EN55022-B compliant
|
CE marking |
Low voltage and EMI directive and RoHS2.0 |
EMS immunity |
Electrostatic discharge: EN61000-4-2 compliant Radiated, radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips and fluctuation: EN61000-4-11 compliant |
MTBF |
200,000H |
Operating temperature |
-10 to 60 deg C. |
Leakage current |
0.5mA max. at AC 100V/1mA max. at AC 240V
|
Cooling systems |
Air-cooling without blower |
Insulation |
AC1500V/min between AC input and FG/DC output 50 ohm min between AC input and DC output/FG and between DC output and FG |
Output ground connection |
Capacitor ground |
Warranty |
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |