Nipron Site MapContact us
Home Second Generation Power SupplySecond Generation Power Supply
PCFL-180P-X2S2
1U/2U uncomplianceCompactPCI uncomplianceVMEbus uncomplianceERP uncomplianceRedundant uncomplianceOther complianceSSI-DPS uncompliance
Stocked product Inquiry / Quotations
Fanless ATX power supply with backup function
 PCFL-180P-X2S2 •Natural air cooling design•Individual output performs rated power operation even zero load at other outputs.

•Easily customized to multi-output power supply by replacing output units. (5ch max.)
Continuous
90W
Peak
180W
* Output harnesses are optional.
* The signal for shutdown is delivered from Battery Package.
*Please use Metric Screw Threads, ("M3" screws) for PSU mounting.(Inch Screw Threads cannot be used.)
Function :For description of function, click each icon
DC Startup uncomplianceRS232C uncomplianceTTL uncomplianceSilent complianceRoHS Directive complianceConnection compliancePFC complianceLead-free uncompliance5VSBFAN uncomplianceTSFCFAN uncomplianceUSB uncompliance
Output specification
Output specification ,Continuous 90W,Peak Capacity 180W
Output connector: For description of function, click each icon
Output connector for ATX Mother Board compliance ATX 12V ver. 2.0 or later power supply with SSI power connector uncomplianceATX20+4Pin uncomplianceAT motherboard output connector uncomplianceATX Motherboard Auxiliary Connector uncomplianceProcessor connector for ATX motherboard uncomplianceProcessor Connector for SSI Motherboard uncompliancePCI-Express uncompliancePCI-E 8Pin uncompliancePeripheral connector complianceConnector compliant with the S-ATA (Serial ATA) standard complianceConnectors for FDDs compliance
Standard, specifications: For standard and specifications, click each item.
Compatible case size Other
Outline drawing 93Wx55Hx160D
Weight 0.85 kg typ
Input Voltage AC 85-264V
Efficiency AC 77% typical
Power factor 90% min.
Input changeover system Worldwide
Safety UL60950-1, CSA60950-1(c-UL), EN60950-1 (NEMKO), IEC60950-1 (CB report), CE marking
High frequency current regulation Compliant with IEC61000-3-2 (Ed.2.1) Class D
EMI standard
(Input feedback noise)
Compliant with Claas A of VCCI FCC Part15 CISPR 22 and EN55022
CE marking Low Voltage Directive
EMS immunity Compliant with IEC61000-4-5 Level 3
MTBF 100,000H
Operating temperature 0 to 60 deg C.
Leakage current 0.5mA max. at 100Vac/1mA max. at 200Vac
Cooling systems Air-cooling without blower
Insulation
Output ground connection
Warranty Three years after delivery, however, if defects belong to us, the defective unit shall be repaired or replaced at our cost.
Download Product and Technical Information
Instruction Manual Test data Product catalogue product specification