Compatible case size |
Other |
Outline drawing |
128Wx61Hx240D |
Weight |
1.95 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
88% typ(AC115V)/91% typ(AC240V) |
Power factor |
94%min(at 115V AC)/90%min(at 240V AC) |
Input changeover system |
Worldwide |
Safety |
UL60950-1,CSA22.2 No60950-1(c-UL),CCC,and CE Marking(IEC62368-1)
|
High frequency current regulation |
Compliant with IEC61000-3-2 (Ed. 2.1) class A and EN61000-3-2(A14) class A |
EMI standard (Input feedback noise) |
Compliant with VCCI class B FCC Rules class B and EN55022 class B |
CE marking |
Low voltage and EMI directive and RoHS2.0 |
EMS immunity |
Electrostatic discharge to meet EN61000-4-2. Radioactive radio-frequency electromagnetic fields to meet EN61000-4-3 Fast transient burst to meet EN61000-4-4 Lightning surge immunity to meeet EN61000-4-5 Immunity to conducted disturbances, Conductive radio-frequency electromagnetic field to meet EN61000-4-6 Power frequency magnetic field immunity to meet EN61000-4-8 Voltage dips and fluctuation to meet EN61000-4-11 |
MTBF |
90,000H |
Operating temperature |
-10 deg C to 70 deg C |
Leakage current |
0.5mA max. at AC115V and 1.0mA max. at AC240V |
Cooling systems |
Forced air cooling |
Insulation |
|
Output ground connection |
|
Warranty |
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |