Compatible case size |
Other |
Outline drawing |
75Wx36Hx160D |
Weight |
0.31 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
91.5% typ(AC100V)/93.5% typ(AC200V) |
Power factor |
99% typ(AC100V)/90% typ(AC200V) |
Input changeover system |
Worldwide |
Safety |
IEC60601-1,CSA22.2 No 601.1,ANSI/AAMI ES60601-1
CE marking,DENAN(section2) compliant. |
High frequency current regulation |
IEC61000-3-2 (ed.2.1) class D EN61000-3-2 (A14) class D compliant |
EMI standard (Input feedback noise) |
VCCI-B FCC-B CISPR22-B EN55022-B compliant |
CE marking |
Low Voltage Directive, EMC Directive |
EMS immunity |
Electrostatic discharge: EN61000-4-2 compliant Radiate, radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips and fluctuation: EN61000-4-11 compliant |
MTBF |
|
Operating temperature |
-10 to 70 deg C |
Leakage current |
0.06mA at Rated Load/0.12mA at Rated Load |
Cooling systems |
Air-cooling without blower |
Insulation |
|
Output ground connection |
Capacitor ground |
Warranty |
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |