Ultra high efficiency AC-DC PCB switching PSU (30V output, nylon connector type)
|
|
-Continuous 350W/500W, peak 600W high power. -With ultra high efficiency and low losses, reduce CO2 emission and save energy. -Achieving the low power consumption at standby mode (at remote OFF). (With extra 5V standby power supply board, ErP directive Lot6 complyant ) -Complying with medical standard IEC 60601-1 2nd/3rd. (Acquisition models will be added in our lineup). -With current balancing circuit, easily parallel-operatable. - Output voltage adjusting volume available. -Output On/OFF control function. -Output voltage remote sensing function. -Noise reduction circuit. -Low noise & Low leakage current, without external noise filter. -Double-sided PCB with through-hole. |
|
Continuous
351W |
|
Peak
600W |
|
|
|
|
Output specification
Standard, specifications: For standard and specifications, click each item.
Compatible case size |
Other |
Outline drawing |
95Wx47Hx222D |
Weight |
0.65 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
92%typ(AC100V)/94%typ(AC200V) |
Power factor |
99%typ(AC100V)/94%typ(AC200V) |
Input changeover system |
Worldwide |
Safety |
UL/CSA/IEC60950-1,CE marking(IEC62368-1),PSE (Ordinance item2) compliant |
High frequency current regulation |
IEC61000-3-2 (ed.2.1) class D EN61000-3-2 (A14) class D compliant |
EMI standard (Input feedback noise) |
VCCI-B FCC-B CISPR22-B EN55022-B compliant |
CE marking |
Low Voltage Directive, EMC Directive |
EMS immunity |
Electrostatic discharge: EN61000-4-2 compliant Radiate, radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips and fluctuation: EN61000-4-11 compliant |
MTBF |
|
Operating temperature |
-10 to 60 deg C (With natural cooling)/-10 to 70 deg C (With forced air cooling) |
Leakage current |
0.09mA at Rated Load, 0.19mA at Load ratio Max 5%(AC100V) 0.17mA at Rated Load, 0.23mA at Load Ratio Max 5% (AC200V) |
Cooling systems |
Air-cooling without blower |
Insulation |
|
Output ground connection |
Capacitor ground |
Warranty |
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |
Compatible battery pack (Separately sold):When each icon is clicked, corresponding description is displayed.
Download Product and Technical Information
|