Compatible case size |
Other |
Outline drawing |
83Wx83Hx252D |
Weight |
0.74 kg typ |
Input Voltage |
AC |
85-264V |
Efficiency |
AC |
82% typ(AC100V)/85% typ(AC200V) |
Power factor |
99% typ( AC100V) / 92% typ(AC200V) |
Input changeover system |
Worldwide |
Safety |
UL60950-1, CSA60950-1(c-UL), and CE Marking, PSE (Ordinance item2) compliant |
High frequency current regulation |
IEC61000-3-2 (ed.2.1) class D EN61000-3-2 (A14) class D compliant |
EMI standard (Input feedback noise) |
VCCI-B FCC-B CISPR22-B EN55022-B compliant |
CE marking |
Low voltage and EMI directive |
EMS immunity |
Electrostatic discharge: EN61000-4-2 compliant Radiate, radio frequency electromagnetic fields: EN61000-4-3 compliant Fast transient burst: EN61000-4-4 compliant Lightning surge: EN61000-4-5 compliant Conductive radio frequency electromagnetic fields: EN61000-4-6 compliant Power source frequency magnetic immunity: EN61000-4-8 compliant Voltage dips and fluctuation: EN61000-4-11 compliant |
MTBF |
|
Operating temperature |
-10 to 60 deg C |
Leakage current |
0.09mA at Rated Load, 0.19mA at Load ratio Max 5%(AC100V) 0.17mA at Rated Load, 0.23mA at Load Ratio Max 5% (AC200V) |
Cooling systems |
Air-cooling without blower |
Insulation |
AC 3kV for one minute between Input and Output/RC/AC FAIL.AC 2kV for one minute between Input and FG.AC 500V for one minute among DC output, RC, AC FAIL, and FG. |
Output ground connection |
Capacitor ground |
Warranty |
Three years after delivery; the defective unit shall be repaired or replaced at our cost if defects belong to us. |