450W Nonstop Power Supply (RS232C signal type) Long-life Design of 10 Years at 45 deg. C
|
|
-Backup function protects PCs at blackout -Independent voltage-stabilizing circuit adopted in all outputs, all outputs have the minimum load of 0A, stably drives the latest high-performance CPU -Thermo-sensing speed control fan allows for a quiet environment; variable fan speed switch dedicated to reduce heat of CPU -Connector system is adopted to adjust to various output connectors -Signal unit and cooling fan can be replaced |
|
Continuous
350W |
|
Peak
450.5W |
|
|
*Output Harnesses are optional. Removable Harness full-set WHS2828 is recommended. |
*Please use Metric Screw Threads, ("M3" screws) for PSU mounting.(Inch Screw Threads cannot be used.) |
Function :For description of function, click each icon
Output specification
Output connector : For description of function, click each icon
Standard, specifications: For standard and specifications, click each item.
Compatible case size |
PS2 |
Outline drawing |
150Wx86Hx140D |
Weight |
1.80 kg typ |
Input Voltage |
AC |
85-264V |
DC |
24V (Dedicated battery package only) |
Efficiency |
AC |
73% typical at AC100V and 77% typical at AC240V |
DC |
73% typical at 24V DC |
Power factor |
99% typical at AC100V, and 97% typical at AC240V |
Input changeover system |
Worldwide |
AC, DC input |
Battery only for DC input |
Safety |
UL60950, CSA60950 (c-UL), EN60950, and CE marking |
High frequency current regulation |
Compliant with IEC61000-3-2 (Ed. 2.1) class D and EN61000-3-2(A14) class D |
EMI standard (Input feedback noise) |
Compliant with VCCI class B FCC Rules class B and EN55022 class B |
CE marking |
Low Voltage Directive |
EMS immunity |
Electrostatic discharge to meet EN61000-4-2. Radioactive radio-frequency electromagnetic fields to meet EN61000-4-3 Fast transient burst to meet EN61000-4-4 Lightning surge immunity to meeet EN61000-4-5 Immunity to conducted disturbances, Conductive radio-frequency electromagnetic field to meet EN61000-4-6 Power frequency magnetic field immunity to meet EN61000-4-8 Voltage dips and fluctuation to meet EN61000-4-11 |
MTBF |
83,000H |
Operating temperature |
0 to 45 deg C with full-load and to 60 deg C with 70% of load |
Leakage current |
0.5mA max. at AC100V and 1mA max. at AC200V |
Cooling systems |
Forced air cooling |
Insulation |
|
Output ground connection |
Connected to chassis |
Signal unit |
SU-RS (RS232C),SU-BU (Buzzer) ,SU-US2 (USB) |
Warranty |
Three years after delivery. However, if defects belong us, the defective unit shall be repaired or replaced at our cost. |
Automatic shutdown compatible OS:Click here for more information and installation.
Compatible battery pack (Separately sold):When each icon is clicked, corresponding description is displayed.
Accessory (Optional)
Download Product and Technical Information
|